5 Installation at Site
34 of 72
Ama-Drainer-Box
Fig. 21:
Removing the protective casing with a screwdriver
733.12
733.12
720.02
719.01
854
720.03
719.01
Hose
720.02
Hose nozzle with union nut
720.03
Hexagon reducing nipple
733.12
Hose clip (2)
854
Check valve
Ama-Drainer 4../35 SE, SD
NOTE
For connecting the discharge line, permanently remove the protective casing 13-16
fitted to the submersible motor pump. To do so, insert a flat-head screwdriver no
more than 2 mm into the recesses provided for this purpose in the protective
casing, and lever up the protective casing.
Fig. 22:
Removing the protective casing with a screwdriver