![KSB Ama-Drainer-Box Operating Manual Download Page 30](http://html.mh-extra.com/html/ksb/ama-drainer-box/ama-drainer-box_operating-manual_2006544030.webp)
5 Installation at Site
30 of 72
Ama-Drainer-Box
1
2
3
1
2
3
Installing the collecting tank of Box 1
Installing the collecting tank of Box Z2 B
1
Collecting tank 591
2
Set of pads 99-32
3
Set of fasteners 99-31
5.4.2 Connecting the above-floor box piping
CAUTION
Stresses and strains at the piping
Impermissible load acting on the collecting tank!
▷
Connect the piping without transmitting any stresses or strains; make sure that
no forces and moments act on the collecting tank.
Protect the piping against frost.
Connections
▪
Support the piping weights on site.
▪
All tank nozzles are closed.
5.4.2.1 Inlet and vent line
A
A
Fig. 18:
Opening the nozzles
▪
Open the inlet and vent nozzles selected using a saw or angle grinder and debur
the cut edges (
▼
A).
▪
Connect the inlet and vent line using commercial connection elements, e.g. PVC-
KG socket or parts without sockets.
NOTE
The collecting tanks are equipped with cable entries for pump power and control
cables.
Connections
(
ð
Section 5.5.1.3, Page 37) (
ð
Section 5.5.2.2, Page 41)
As an option, the vent line or a free connection nozzle with separate conduit can
be used as a cable duct.
5.4.2.2 Connecting the discharge line
CAUTION
Incorrect installation of discharge line
Leaks and flooding of installation room!
▷
Run the discharge line above the flood level before leading it into the sewer.
▷
Do not connect the discharge line to the downpipe.
▷
Do not connect any additional sanitary installations to the discharge line.
Summary of Contents for Ama-Drainer-Box
Page 1: ...Automatic Waste Water Lifting Unit Ama Drainer Box Installation Operating Manual ...
Page 64: ...9 Related Documents 64 of 72 Ama Drainer Box ...
Page 69: ......
Page 70: ......
Page 71: ......