8.7 Bale Counter
The control unit comfort bale counter has two displays.
This makes it possible to record the number of round bales
baled for two different time spans.
All round bales are recorded according to the following
conditions:
a) the bale density has reached at least the number 0
b) the binding or net wrapping process was initiated
c) the sensor on the twine or net wrapping mechanism
has received at least 50 pulses
d) the bale chamber has been relocked following ejection
of the bale
Display bale counter
• Press the bale counter key (4)
During baling material pick-up the display reverts to
operating mode.
Resetting the bale counter
The two counters can be set to “
0
” separately.
Upper bale counter display:
• press the program key (13)
Bales pie.:........0
Lower bale counter display:
• Press the quit key (15)
Bales tot.:........0
#
1
2
5
6
7
8
9
0
3
4
VP-1-021
4
STOP
Bales pie.:.......10
Bales tot.:......345
pie.-- erase--- tot.
Prog
Quit
#
1
2
5
6
7
8
9
0
3
4
VP-1-022
STOP
13
15
Bales pie.:.......10
Bales tot.:......345
pie.-- erase--- tot.
Summary of Contents for Round Pack 1250
Page 20: ...II 10 Safety ...
Page 34: ...IV 6 Use ...
Page 61: ...V 27 Basic Settings and Operation ...
Page 62: ...V 28 Basic Settings and Operation ...
Page 84: ...VIII 16 Control unit Comfort ...
Page 96: ...IX 12 Maintenance VP100101 1 Z 2a 9 H L 4 a1 11 12 I II 5 3 3 2b a2 H L 6 Z m in 0 2a 2b 7 7 ...
Page 111: ...IX 27 Maintenance ...
Page 112: ...IX 28 Maintenance ...
Page 114: ...X 2 Winter Storage ...
Page 122: ...XII 6 Faults Causes and Remedy ...
Page 134: ...A 12 Appendix ...
Page 135: ...A 13 Appendix ...