Maintenance
323
Pos: 59.184 /Überschriften/Überschriften 3/A-E/E/Elektromagnetventile @ 76\mod_1309953878084_78.docx @ 665615 @ 33 @ 1
13.18.6
Electromagnetic Valves
Pos: 59.185 /BA/Wartung/Rundballenpresse/Bild Elektromagnetventil CF/CV @ 76\mod_1309946039177_78.docx @ 665307 @ @ 1
RPN00101
2
1
Fig. 255
Pos: 59.186 /BA/Wartung/Rundballenpresse/Elektromagnetventil CF/CV @ 76\mod_1309946503643_78.docx @ 665335 @ @ 1
The electromagnetic valves (2) are located on the left-hand side of the machine behind the
guard.
A emergency manual activation of the motional function of the pick-up and the blade base can
be carried out on the electromagnetic valves, if the comfort controls fails.
In the event the comfort electronic system fails:
•
Screw in the rear subjacent slot screw (1) or the knurled head screw until the pick-up can be
lifted or lowered directly from the position of the control valve on the tractor
Note
As soon as the comfort electronic system works correctly again, the slot screw or the knurled
head screw on the electromagnetic valve have to be screwed out. Only this guarantees the
operation of the pick-up via the operation terminal.