2.1 Device description
Vortex flowmeters measure and display the flow of flammable and non-flammable gases, steam
and liquids. They transmit a 4...20 mA or digital multidrop, and a pulse output signal, as
applicable, using HART
®
communication protocol for remote configuration, calibration and
monitoring.
2.2 Marking
The marking of the devices is shown on the nameplate below. On both the compact devices and
the remote versions, the main plate is located on the signal converter housing. When the
flowmeter is remotely mounted, the junction box on the flow sensor body has a nameplate
showing its hazardous location rating.
Compact devices with two signal converters for dual measurement (Dual Version) are each
marked with a nameplate. The details relevant to explosion protection are identical on both
nameplates.
Figure 2-1: Example of a nameplate for the compact version
1
Model number and serial number
2
Marking according to the notified body
3
Note for disposal
4
Manufacturer logo
5
IP rating for enclosure
6
Manufacturer address
7
Note for electrical data
8
Warning for opening enclosure in hazardous areas
SEE CERTIFICATE FOR ELECTRICAL DATA.
WARNING
EXPLOSION HAZARD
Do not open when an explosive gas or dust atmosphere is present.
• Substitution of components may impair suitability for intrinsic
safety.
• Do not open when energized.
Failure to follow these instructions can result in death
or serious injury.
!
47058 DUISB
URG GERMANY
ST.
S/N ORIGIN
SUPPLY MWP @ 100° F (38°C)
MAX. AMB. TEMP. 176°F (80°C) MAX. PROC. TEMP.
REF K-FACT. PULSES / ft
3
- PULSES / liter
K-FACTOR PULSES /
CUST. TAG
CABLE ENTRIES
IP 66 ENCLOSURE
SIRA 19ATEX2001X
II 2/1 (1) G II 2D
Ex db [ia Ga] ia IIC T4 Gb
Ex tb IIIC T85°C Db
THIS PRODUCT IS PROTECTED BY THE FOLLOWING PATENTS:
US 7,212,928; US 7,853,415; US 9,322,683; (Model 84C)
AND EP 1585943. ADDITIONAL PATENTS ARE PENDING.
KR
OHNE MESSTECHNIK GMBH
!
MODEL
CERT No: SIRA19ATEX2001X
When used with a Remote Sensor Housing it must bear