DEVICE DESCRIPTION
2
9
OPTISWIRL 5080
www.krohne.com
07/2020 - 4008054001 - AD OPTISW5080 Exd Gb-Db en R01
WARNING!
Process temperatures above 130
°
C / 266
°
F are permitted only if the temperature 80
°
C / 176
°
F at
the housing reference point is not exceeded during operation. The operator has to ensure the
temperature limit by temperature measurements at the housing reference point. For high
temperature applications positioning the electronics housing to the side or bottom and/or piping
insulation is recommended to assure the temperature limit is not exceeded.
INFORMATION!
The housing reference point is located next to the flowmeters external ground terminal.
INFORMATION!
When the LCD indicator is used, the low temperature limit is -20
°
C / -4
°