6
TECHNICAL DATA
36
OPTIMASS 2000
www.krohne.com
08/2014 - 4000810003- MA OPTIMASS 2000 R03 en
6.4 Guidelines for maximum operating pressure
Notes:
•
Ensure that the meter is used within its operating limits
•
All hygienic process connections have a maximum operating rating of 10 barg
at 130
°
C / 145 psig at 266
°
F
Linear de-rating of PED certified secondary containment
Pressure / temperature de-rating, all meter sizes in metric (flanged connections as
Pressure / temperature de-rating, all meter sizes in metric (flanged connections as
Pressure / temperature de-rating, all meter sizes in metric (flanged connections as
Pressure / temperature de-rating, all meter sizes in metric (flanged connections as
per EN 1092-1:2007)
per EN 1092-1:2007)
per EN 1092-1:2007)
per EN 1092-1:2007)
X temperature [
°
C]
Y pressure [barg]
1
Measuring tube (UNS S32760) PED certification
2
Measuring tube (UNS S31803) PED certification
3
Measuring tube (UNS S31803 / S32760) FM certification
4
Measuring tube (UNS S31803) CRN certification
Outer cylinder material
-45
°
C
20
°
C
130
°
C
304 / L or 316 / L
40 barg
40 barg
32 barg
UNS S31803
150 barg
150 barg
100 barg