TECHNICAL DATA
6
31
OPTIMASS 2000
www.krohne.com
08/2014 - 4000810003- MA OPTIMASS 2000 R03 en
On site calibration
±
0.5 kg/m
3
/
±
0.033 lbs/ft
3
Temperature
Temperature
Temperature
Temperature
Accuracy
±
1
°
C /
±
1.8
°
F
Operating conditions
Maximum flow rates
Maximum flow rates
Maximum flow rates
Maximum flow rates
S100
420000 kg/h / 14698 lbs/min
S150
900000 kg/h / 33804 lbs/min
S250
2300000 kg/h / 84510 lbs/min
Custody transfer flow rates (mass)
Custody transfer flow rates (mass)
Custody transfer flow rates (mass)
Custody transfer flow rates (mass)
S100
11000...220000 kg/h / 404...8083 lbs/min
S150
25000...500000 kg/h / 919...18371 lbs/min
S250
60000...1200000 kg/h / 2205...44092 lbs/min
Custody transfer flow rates (volume)
Custody transfer flow rates (volume)
Custody transfer flow rates (volume)
Custody transfer flow rates (volume)
S100
11...220 m
3
/h / 1660...33210 bbl/day
S150
25...500 m
3
/h / 3774...75478 bbl/day
S250
60...1200 m
3
/h / 9057...181147 bbl/day
Assumes operating density 1000 kg/m
3
/ 62.4 lb/ft
3
Ambient temperature
Ambient temperature
Ambient temperature
Ambient temperature
Compact version with Aluminium
converter
-40...+60
°
C / -40
…
+140
°
F
Extended temperature range: 65
°
C / 149
°
F for some I/O options. For more
information contact manufacturer.
Compact version with Stainless Steel
converter
-40...+55
°
C / -40
…
+130
°
F
Remote versions
-40...+65
°
C / -40
…
+149
°
F
Process temperature
Process temperature
Process temperature
Process temperature
Flanged connection
-45
…
+130
°
C / -49
…
+266
°
F
Nominal pressure at 20
Nominal pressure at 20
Nominal pressure at 20
Nominal pressure at 20
°
C / 68
C / 68
C / 68
C / 68
°
F
F
F
F
Measuring tube (Duplex UNS S31803)
Measuring tube (Duplex UNS S31803)
Measuring tube (Duplex UNS S31803)
Measuring tube (Duplex UNS S31803)
PED 97/23/EC
-1
…
150 barg / -14.5
…
2175 psig
FM
-1
…
140 barg / -14.5
…
2030 psig
CRN / ASME B31.3
-1
…
100 barg / -14.5
…
1450 psig
Measuring tube (Super Duplex UNS S32760)
Measuring tube (Super Duplex UNS S32760)
Measuring tube (Super Duplex UNS S32760)
Measuring tube (Super Duplex UNS S32760)
PED 97/23/EC
-1
…
180 barg / -14.5
…
2610 psig
FM
-1
…
140 barg / -14.5
…
2030 psig
CRN / ASME B31.3 (pending)
-1
…
130 barg / -14.5
…
1885 psig
Outer cylinder
Outer cylinder
Outer cylinder
Outer cylinder
Non PED / CRN approved
Typical burst pressure > 100 barg / 1450 psig
PED approved secondary containment
-1...40 barg / -14.5...580 psig
-1...150 barg / -14.5...2175 psig (Duplex option)
Fluid properties
Fluid properties
Fluid properties
Fluid properties
Permissible physical condition
Liquids, gases, slurries
Permissible gas content (volume)
Contact manufacturer for information.
Permissible solid content (volume)
Contact manufacturer for information.
MA_OPTIMASS_2000_en_150206_4000810003_R03.book Page 31 Wednesday, September 30, 2015 5:42 PM