08/2014 - 4000810003- MA OPTIMASS 2000 R03 en
Protection category (acc. to EN 60529)
IP 67, NEMA 4X
Installation conditions
Inlet runs
None required
Outlet runs
None required
Materials
Measuring tube
Stainless Steel UNS S31803 (1.4462)
Optional UNS S32760 (1.4410)
Spigot
Stainless Steel UNS J92205 (1.4470)
Optional UNS J93404 (1.4469)
Flanges
Stainless Steel AISI 316 / 316L (1.4401 / 1.4404) dual certified
Optional Stainless Steel UNS S31803 (1.4462) (NACE approved)
Optional UNS S32760 (1.4410) (NACE approved)
Outer cylinder
Stainless Steel AISI 304 / 304L (1.4301 / 1.4307) dual certified
Optional Stainless Steel AISI 316 / 316L (1.4401 / 1.4404) dual certified
Optional Stainless Steel UNS S31803 (1.4462)
1
Heating jacket version
Heating jacket version
Heating jacket version
Heating jacket version
Heating jacket
Stainless Steel 316L (1.4404)
Note: the outer cylinder is in contact with the heating medium
All versions
All versions
All versions
All versions
Sensor electronics housing
Stainless Steel 316L (1.4409)
Optional Stainless Steel 316 (1.4469)
Junction box (remote version)
Die cast Aluminium (polyurethane coating)
Process connections
Flange
Flange
Flange
Flange
DIN
DN100
…
300 / PN16
…
160
ASME
4...12" / ASME 150
…
1500
JIS
100A / 10...20K
Electrical connections
Electrical connections
For full details, including: power supply, power consumption etc., see
technical data for the relevant converter.
I/O
For full details of I/O options, including data streams and protocols, see
technical data for the relevant converter.
MA_OPTIMASS_2000_en_150206_4000810003_R03.book Page 32 Wednesday, September 30, 2015 5:42 PM