Operation & Installation Manual V12-V6 2010-05-31.doc
31/05/2010
56/60
8
Technical specifications
Flow Velocity Range
flow rate
flow rate
minimum maximum
[m³/h]
[m³/h]
4 "
20
800
6 "
32
1800
8 "
40
3100
10 "
50
4800
12 "
65
6600
14 "
80
8000
16 "
120
10100
18 "
130
12500
20 "
200
14800
24 "
285
20600
Diameter Range
100 / 4”, 150 / 6”, 200 / 8”, 250 / 10”, 300 / 12”, 350 / 14”, 400 /
16”, 450 / 18”, 500 / 20”, 600 / 24”, extended range: 750 / 30” –
1600 / 64”
Pressure Range
150lbs, 300lbs, 600lbs, 900lbs,
extended range up to 2500lbs (optional)
4. Operating Conditions
Process conditions
Minimum 4 bara
Pressure
ANSI150 – ANSI900,
High pressure version ANSI1500, ANSI2500 optional
Temperature: Process
Transducer type G5: -40 - + 70
°
C,
Transducer type G6: -40 - + 100
°
C
Temperature :
Ambient -40 - +60
°
C
Temperature :
Storage -50 - +70
°
C
Rel. Density
≥
0,55
Fluids
Natural gas with methane concentrations between 75% and
100%, liquid rate < 0,1 vol. %; reduced accuracy for liquid rates
between 0,1vol% and 1vol%