GROUND TERMINAL
Ground terminal (1) connects the earth line for
prevention of electric shock. When the electric device
is earthed, always the generator must be earthed.
PARALLEL OPERATION OUTLETS
(not applicable for this model)
This is the terminal for connecting special cables
for parallel running of two generator. The parallel
running requires two generators and a special cable.
(The rated output in parallel running is 6,0 kW and
the rated current is 26A/230V.
BRAKE
During the operation and idle period of machine,
brake timely and switch to “STOP”. In case of the
machine required to be move, switch the brake to
“RUN”.
PRE-OPERATION
Pre-operation checks should be made each time you
need to operate
The engine and muffler will be very hot after the
engine has been run. Avoid touching the engine and
muffler while they are still hot with any part of your
body or clothing during inspection or repair.
FUEL
• Fuel is highly flammable and poisonous. Check
“SAFETY INFORMATION” carefully before filling.
• Do not overfill the fuel tank, otherwise it may
overflow when the fuel warms up and expands.
• After fill the fuel, make sure the fuel tank cap is
tightened securely. Immediately wipe off spilled
fuel with a clean. Use only unleaded gasoline. The
use of leaded gasoline will cause severe damage to
the internal engine parts.
Remove the fuel tank cap
1. Fuel level gauge.
Recommended fuel
Unleaded gasoline (95 octan)
Tank capacity: 10,0 liter
TIP: Gasoline will deteriorate after time, and old
gasoline might cause startup problems. Make sure to
use fresh gasoline.
ENGINE OIL
The generator has been shipped without engine
oil. Do not start the engine until filled with the
sufficient engine oil. Do not tilt the generator when
adding engine. This could result in overfilling and
damage to the engine.
RECOMMENDED ENGINE OIL
Engine oil
SAE 10W -30
Engine oil grade
API Service SE type, or
higher quality.
Engine oil quantity 0,6 liter
CHECKLIST BEFORE USE
a) FUEL (read page 29)
• Check fuel level
• Refill if needed
b) ENGINE OIL (read page 29)
• Check engine oil level
• If level is too low, please refill with recommended
oil until specified level
• Check if any oil leackages
Never operate the engine in a closed area or it may
cause unconsciousness and death within a short
time. Operate the engine in a well ventilated area.
Before starting the engine, do not connect any
electric devices.
Always check the condition of the generator before
use. The generator has been shipped without engine
oil. Do not start the engine till fill with the sufficient
engine oil.