22
23
English
English
CONTROL FUNCTIONS
”3 in 1” SWITCH KNOB
1. Engine switch/fuel valve “OFF”; Ignition circuit is
switched off. Fuel is switched off. The engine will
not run.
2. Engine switch \fuel valve \chock “ON”; Ignition
circuit is switched on. Fuel is switched on. Chock is
switched on. Position for running the engine.
3. Engine switch \fuel valve \chock “ON”; Ignition
circuit is switched on. Fuel is switched on. Chock is
switched on. Position for starting the engine.
TIP: The choke is not required to start a warm
engine.
DIGITAL DISPLAY METER
1. Multimeter
2. Liquid crystal display
3. Operating key
4. Oil warning light
5. Overload indicator
light
6. AC pilot light
Normal operation: During the normal operation,
the operation key (3) for switching the display
and recycling showing: voltage-current-power-
accumulative time-current time.
In case of failed operation:
U>
a: AC over voltage, indicating the character of AC
(alternative indication of AC and digit).
b: DC over voltage, indicating the character of DC
(alternative indication of DC and digit).
U<
a: AC under-voltage, indicating the character of AC
(alternative indication of AC and digit).
b: DC under-voltage, indicating the character of DC
(alternative indication of DC and digit).
I> Output power by generator
Output short cicuit of generator
Over heat of generator
Maintenance time
OIL WARNING LIGHT
When the oil level falls below the lower level, the
oil warning light comes on and the engine stops
automatically. Unless you refill with oil, the engine
will not start again.
TIP: If the engine stalls or does not start, turn the
engine switch to “ON” and then pull the recoil starter.
If the oil warning light flickers for a few seconds, the
engine oil is insufficient. Add oil and restart.
OVERLOAD INDICATOR LIGHT (RED)
The overload indicator light (1) comes on when an
overload of a connected electrical device is detected,
the inverter control unit overheats, or the AC output
voltage rises. Then, the AC protector will trip,
stopping power generation in order to protect the
generator and any connected electric devices. The
AC pilot light (Green) will go off and the overload
indicator light (Red) will stay on, but the engine will
not stop running.
When the overload indicator light comes on and
power generation stops, proceed as follows:
1. Turn off any connected electric devices and stop
the engine.
2. Reduce the total wattage of connected electric
devices within the rated output.
3. Check if there are any ventilation blockage, in case
remove blockage.
4. When above instructions are completed, please
restart engine.
TIP: The overload warning light may light and light
for a few seconds when used electrical equipment
requiring high starting current. Examples of this
may be submersible lens pumps and chainsaws.
This is consequently no indication that an error has
occurred.
AC PILOT LIGHT (GREEN)
The AC pilot light (1) comes on when the
engine starts and produces power.