KREMLIN REXSON
Page 6
Manual : 573.191.112
Captions :
1
Fluid module
7
Electrovalves
2
Control bay
8
Air flow switch
3
Display unit
9
Color changer
9a : base CTM
9b : cata CTM
4
Volumeters
10
Protective housing
5
Automatic valve
11
Three-way valve
6
Mixer
12
Non-return valve
CABINET FRONT PART
Ind.
Description
Function
-
Red LED
Fault
-
Orange LED
Operating (except production)
-
Green LED
Production
The machine is totally programmable via a man/machine interface. The screen indicates continuously by a
simple identification, the statuses of the machine and enables to have access to the essential
functionalities: ON / OFF - FLUSHING -PRODUCTION
The informations relating to the operating of the machine (real-time display of the ratio, of the
consumption…) can be read on the LCD screen.
The CYCLOMIX
TM
MICRO saves continuously the instantaneous consumptions of base, catalyst and
solvent as well as the total consumptions and the emissions of Volatile Organic Compounds (VOC) during
the operating of the machine.
On the machine bay, there is a cord grip. It enables to supply electricity to the machine via a safety
isolating switch (115V / 230V).
Do not use electrostatic spraying for water-based paints or paints with a
resistivity lower than 5 M
:
.