IMPLANTATION
There are different ways to install the CYCLOMIX
TM
MICRO to answer to the majority of installations.
Nevertheless, some installations are forbidden because dangerous.
The display unit must be moved 1 m / 3.3 ft away from the fluid module and not be installed
above that one.
Fixing the display unit on the fluid module is forbidden.
Correct installation :
the display unit is not fixed to the fluid module.
Incorrect installation :
the display unit is fixed to the fluid module.
Correct installation :
The display unit is installed in a safe area.
The fluid module is in a safe area or Z2.
Incorrect installation :