KREMLIN REXSON
Page 36
Manual : 573.191.112
16. DISASSEMBLY - REASSEMBLY
Stop the machine after its flushing.
Depressurize the systems.
The machine is manufactured under the ATEX agreement and can not be modified.
KREMLIN REXSON will not be held responsible for any failure to comply with that
instruction.
Guards (air motor cover, coupling shields, connectors,…) have been designed for
safe use of the equipment.
The manufacturer will not be held responsible for bodily injury or failure and / or
damage to property due to removal or partial removal of the guards.
MIXER
Unscrew the mixer assembly and replace it with a new one.
FLOWMETER
The flowmeters consist of an electronic sensor
(1) and of a mechanical part that is composed
of bearings and gearings.
To remove the flowmeter : disconnect the
connector (2) and unscrew the sensor (1).
Then loosen the screws (3) of the mechanic
part. Once the screws removed, open the
flowmeter paying attention to the seal (4) and to
the gearings (5). Clean the different elements
then reinstall.
5
4
3
1
2