KREMLIN REXSON
Page 14
Manual : 573.191.112
CONNECTION OF THE CONTROL BAY AND OF THE FLUID PART
Â
The CYCLOMIX
TM
MICRO must be
connected
to
a
dry
and
clean
compressed air (minimum 4 bar / 58 psi)
and to a single phase electric supply
(115 V / 230V) connected to an isolating
switch. The network ground will be
connected in the control bay on a contact
provided.
Before
connecting
the
CYCLOMIX
TM
MICRO, be certain the
mains voltage is the same than the
one
of
the
machine
(230
V).
If no, open the electric box removing the
protective housing (10) and shift the
staple (230V
Æ
115V).
The air connection of the machine is
Female 1/4 G (air inlet = R1 and air outlet
= R2).
The connection between the control bay
and the fluid module is carried out via the
provided cable, length 5 m / 196.85 ft. For
lengths up to 5 m / 196.85 ft connect the
cables between them (male-female).
The connection between the two
cables must not be in the explosive area.
A valve fitted with fittings is supplied with
the machine. It will be mounted on the
gun air inlet : it enables to shut off quickly
the fan air (priming, flushing stage).
Fuse 160 mA
for machine with serial number < to 09Y1080
Fuse 315 Ma
for machine with serial number >to 09Y1080
Connection of the fluid inlets :
The fluid inlets are M 1/2 JIC.
Â
We advice you to install AIRMIX
filters on the fluid inlets (catalyst and
base).
The base(s) and the base solvent are
connected on the color changer installed
on the machine.
The catalyst is connected :
- directly on the elbow installed before the
non-return valve,
- or on the color changer (cata and cata
solvent) installed in the machine.
It depends upon the configuration of the
machine.
The air connection is made on the two
G 1/4 connecting parts.
Air
inlet /
outlet
Base(s) and solvent base
Catalyst