PILOTED VALVES (FLUID VALVES AND TEST VALVES)
1
2
3
4
5
6
8
9
10
11
11
13
14
15
16
7
CARTRIDGE OF A FLUID VALVE (Ind. 9)
Loosen the 3 screws (7) and take off the valve from the module body.
Unscrew the needle (1).
Unscrew the cylinder (4).
Hold the rod strainer (6), unscrew the needle rod and remove the cartridge assembly with rod (9).
Assemble the new cartridge (9) into the cylinder support (2) pushing it until the shoulder of the
cartridge rests on the shoulder of that support, then reassemble all parts of the valve in reverse order
of the disassembly.
Present the valve in fronf of the module body.
Center the cartridge (9) on the module body then reassemble the screws (7).
PISTON PACKING (Ind. 14)
Unscrew the cylinder (4).
Remove the spring (5).
Unscrew the opening signal light
(8).
Unscrew the nut (16).
Remove the support washer (15)
and the packing (14).
Clean the parts and change them if
necessary.
Before reassembling :
Before assembling on the piston
(13), take care of shaping the
cartridge lip (14) by hand as
shown in the above drawing
(cartridge
turned
up
on
the
piston).
The nut (16) must be glued on the
piston (13) with loctite adhesive
(eg : Loctite 222).
13
14
15
16
4
8
5