KREMLIN REXSON
Page 25
Manual : 573.191.112
For the machine wth CATA flushing :
That mode is only available for the CYCLOMIX
TM
MICRO+ and CYCLOMIX
TM
MICRO+ PH versions. A
J7 shunt inside the electric box is also necessary - (refer to"Annexes" - electric diagram, folio 2).
The machine suggests a BASE flushing :
Choose :
- to confirm via
:
the machine opens the solvent valve, starts the counting of the BASE FLUSHING volume and
the buzzer sounds continuously.
- Or to select the CATA FLUSHING (BASE side flushing, then CATA side flushing), via
the
or
keys.
The machine suggests the CATA flushing :
Confirm via
:
the machine opens the BASE solvent valve, starts the counting of the BASE FLUSHING volume
then opens the CATA solvent valve, starts the counting of the CATA FLUSHING volume and the
buzzer sounds continuously.
- Or to select the CATA FLUSHING (CATA side flushing, then BASE side flushing), via the
or
keys.
The machine suggests the CATA flushing :
Confirm via
:
the machine opens the CATA solvent valve, starts the counting of the CATA FLUSHING
volume, then opens the BASE solvent valve, starts the counting of the BASE FLUSHING volume
and the buzzer sounds continuously.
When you begin to flow, the buzzer sounds intermittently and a breakdown begins on the display unit.
The breakdown display evokes the kind of flushing in progress :
BASE : -F-A 9
or
BASE + CATA : -F-Ab9
or
CATA + BASE : -F-bA9
When the breakdown has reached 0, the machine closes the solvent valve and the flushing has ended.
You can stop flushing activating ESC but if so, the machine can be incorrectly
flushed.
The volume of flushing with solvent starts when the flowmeter begins counting. It
means that the time between the validation of the flushing and the opening of the
gun is not taken into account.