8.5 Changing the material nozzle and the air nozzle
Removing the nozzles
1.
Chapter 7.5 ‘Shutting down’ on page 25
).
2.
If necessary, secure the material pressure pump or pressurised material container for the
spray medium against a restart.
Fig. 10: Removing the nozzles
3.
Loosen the cap nut ( Fig. 10/1) and remove together with the air nozzle ( Fig. 10/2).
4.
Actuate and hold the pull lever ( Fig. 10/4).
5.
Unscrew the material nozzle ( Fig. 10/3) with a respective fork wrench.
Always replace the material nozzle ( Fig. 10/3) and the material needle ( Fig. 10/5) at
the same time.
Attaching the nozzles
1.
Actuate and hold the pull lever ( Fig. 10/4).
2.
WARNING!
Risk of injury through the use of incorrect spare parts!
Tighten the material nozzle ( Fig. 10/3) with suitable fork wrench.
3.
Release the pull lever ( Fig. 10/4).
4.
Reinsert the air nozzle ( Fig. 10/2) in the cap nut ( Fig. 10/1) and tighten.
Operating instructions
T-Dok-692-GB-Rev.0
[email protected], www.krautzberger.com
GB–32
Summary of Contents for 200-0415