Kramer Electronics Ltd.
VS-6464DN-EM
– Using the Configuration Menus
28
5. Press TAKE to enter the parameters list.
A message similar to the following is displayed with the relevant port number in place of
06:
IN: 06
SET: Reset Input
6. To select the next parameter press the right arrow button (see
Or:
7. To enter the selected parameter press TAKE.
The parameter options are displayed.
8. Select the required action or number using the keypad numbers and arrows.
9. Press TAKE to save the change.
The parameter change is not implemented on the system until you press TAKE.
10. Repeat from Step 6 to modify additional parameters.
11. Do one of the following:
▪
Press BREAKAWAY to exit the Config Menu.
▪
Wait approximately 15 seconds for the operation to time out.
▪
Press MENU to exit to the parameter list.
Config Menu
—
Output Load Detection Display
This option displays a list of outputs and indicates which have loads attached to them.
To display a list of outputs and attached loads:
1. Press MENU twice.
The following message is displayed:
start configuration menu
MENU to view setup ENTER to change them
2. Press MENU until the following is displayed:
OUT:
01 02 03 04 05 06 07 08 09 10 11
LOAD: o
X
o
o
o
o
X
o
o
o
X
o
indicates that a load is attached and
X
indicates that no load is detected on the relevant
output.
3. Do one of the following:
▪
Press BREAKAWAY to exit the Config Menu.
▪
Wait approximately 15 seconds for the operation to time out.
▪
Press MENU to move to the next Config Menu option.