Kramer Electronics Ltd.
VS-6464DN-EM
– Using the Configuration Menus
30
Config Menu
—
Store Default Setup
This option lets you store the current setup as the default setup. The default setup can be
recalled at any time using the DEFAULT SETUP button (see
This is not the setup that is loaded when the unit is switched on.
To store the current setup as the default setup:
1. Press MENU twice.
The following message is displayed:
start configuration menu
MENU to view setup ENTER to change them
2. Press MENU until the following is displayed:
store DEFAULT setup
press ENTER to store
3. Press ENT to store the current configuration as the default configuration.
The following is displayed:
current matrix stage is OKAY?
press TAKE to confirm
4. Press TAKE.
The following is displayed:
current matrix stage
store as DEFAULT setup
This indicates that the current setup is stored as the default setup. After a few seconds the
next option on the Config Menu is displayed.
Config Menu
—
Total Matrix Reset
This option lets you turn all outputs off or reset the unit to its factory default settings.
To reset the matrix setup:
1. Press MENU twice.
The following message is displayed:
start configuration menu
MENU to view setup ENTER to change them
2. Press MENU until the following is displayed:
TOTAL MATRIX RESET
ESC: exit
ENT: submenu
3. Press ENT to enter the Reset Submenu.
The following is displayed:
COMPLETELY MATRIX RESET
1:ALL outputs OFF 2:Factory default
4. Press 1 to turn off all outputs or 2 to perform a factory reset of all options.