KRAMER: SIMPLE CREATIVE TECHNOLOGY
Controlling the VP-725DSA Presentation Switcher / Scaler
50
Figure 50: Output Setting User Mode Setting Utility Screen
Table 18: User Mode Setting Definitions
User Mode Setting Definitions
HT: Horizontal total
HW: Horizontal sync pulse width
HS: Horizontal active start point
HA: Horizontal active region
HP: Horizontal polarity
VT: Vertical total
VW: Vertical sync pulse width
VS: Vertical active start point
VA: Vertical active region
VP: Vertical polarity
OCLK: Output clock
Confirm: Confirm the action
Discard: Cancel the action
Set Current: Import the values of the currently selected
output resolution into the User Mode Setting
9.1.5.9
Choosing Factory Reset
From the Factory Reset Utility screen (see Figure 51), you can reset your
VP-725DSA
to its preset default setting:
Figure 51: Factory Reset Utility Screen