Get Command syntax
Y Control_Type=1, Function
For example: Y 1,200
Device response:
~id=01Y Control_Type=1, Function, Param
For example: ~01@Y 1,200,3
The following table lists the TP-900UHD “Y commands”.
Description
Function #
Value
Notes
Input Switch Mode
114
0
Input Switch Mode forced by Input Source
parameter (see next item – function 115) or by
Input HDBT/HDMI button (default)
1
Auto Input Switch Mode when signal loss
2
Auto Input Switch Mode to last connected input
Input Source
115
0
HDMI input active
1
HDBT input active
HDMI Input HDCP
capability
116
0
YES – there is HDCP capability
1
NO – input is HDCP non-capable
HDBT Input HDCP
capability
117
0
YES – there is HDCP capability
1
NO – input is HDCP non-capable
Input SIGNAL LOSS
handle mode
118
0
Blue screen – default
1
Black screen
2
Freeze Last Picture
3
Turn off HDMI output 20 sec after signal loss
Output Video
Resolution
200
0
480i/60
1
576i/50
2
720p/50
3
720p/59
4
720p/60
5
1080i/50
6
1080i/59
7
1080i/60
8
1080p/23
9
1080p/24
10
1080p/25
11
1080p/29
12
1080p/30
13
1080p/50
14
1080p/59
15
1080p/60 - DEFAULT
16
1080sf/23
17