24
TP-578H - Protocol 3000
Command -
GEDID
Command Type - System
Command Name
Permission
Transparency
Set:
GEDID
Administrator
Public
Get:
GEDID?
End User
Public
Description
Syntax
Set:
Set EDID data from device
#
GEDID
␠
stage, stage_id
␍
Get:
Get EDID support on certain input/output
#
GEDID?
␠
stage, stage_id
␍
Response
Set:
Multi-line response:
~nn@
GEDID
␠
stage,stage_id,size
␍␊
EDID_data
␍␊
~nn@
GEDID
␠
stage,stage_id
␠
OK
␍␊
Get:
~nn@
GEDID
␠
stage,stage_id,size
␍␊
Parameters
stage -
input/output
stage_id
- number of chosen stage (1.. max number of inputs/outputs)
size -
EDID data size. For Set, size of data to be sent from device, for Get, 0 means no EDID support
Response Triggers
Response is sent to the com port from which the Set (before execution) / Get command was received
Notes
For Get, size=0 means EDID is not supported
For old devices that do not support this command, ~nn@ ERR 002
␍␊
is received