Kramer Electronics Ltd.
KDS-8-MNGR
– Using Embedded Web Pages
38
Managing EDID
Manage and assign EDID to any or all the available encoders. You can assign an EDID from
the 6 default EDIDs, the displays connected to any encoder, or from a user uploaded EDID.
To Assign an EDID to an input on the encoder:
1. In the Menu tabs, select
Settings
. The Group page appears.
2. Click
EDID
. The EDID page appears.
Figure 26: Settings Tab
– EDID Page
3. Under Select Transmitter (that lists all the available encoders and an All button), click
one or more transmitter button (or click
All
) for receiving EDID.
4. Under EDID Options, select an available EDID source:
▪
Click
Load EDID
and select a custom EDID file (*.bin format) from a selection
window on your PC.
In some cases, a custom or external EDID may cause compatibility issues with
certain sources. If this happens, we recommend that you switch to one of the 6
default EDIDs for maximum compatibility.
▪
Click 1 of the following 6 default EDIDs:
Default EDIDs
STD FHD 2CH
1920×1080p@60Hz (4.95Gbps) & 8-bit color, LPCM 2.0
STD FHD MCH
1920×1080p@60Hz (4.95Gbps) & 8-bit color, LPCM 7.1
& Bitstream
STD UHD 2CH
3840×2160p@30Hz (10.2Gbps) & Deep Color
(8/10/12-bit), LPCM 2.0
STD UHD MCH
3840×2160p@30Hz (10.2Gbps) & Deep Color
(8/10/12-bit), LPCM 7.1 & Bitstream
STD UHD+ 2CH
3840×2160p@60Hz (18Gbps) & Deep Color
(8/10/12-bit), LPCM 2.0
STD UHD+ MCH
3840×2160p@60Hz (18Gbps) & Deep Color
(8/10/12-bit), LPCM 7.1 & Bitstream