44
KADS-100/KADS-1/KADS-2 - Protocol 3000
11.2.1
Command Descriptions
Command -
#
Command Type - System-mandatory
Command Name
Permission
Transparency
Set:
#
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Protocol handshaking
#
␍
Get:
-
-
Response
~nn@
␠
OK
␍␊
Parameters
Response Triggers
Notes
Use to validate the Protocol 3000 connection and get the machine number
Command -
AUD-LVL
Command Type - Audio
Command Name
Permission
Transparency
Set:
AUD-LVL
End User
Public
Get:
AUD-LVL?
End User
Public
Description
Syntax
Set:
Set audio level in specific amplifier stage
#
AUD-LVL
␠
stage, channel, volume
␍
Get:
Get audio level in specific amplifier stage
#
AUD-LVL?
␠
stage, channel
␍
Response
~nn@
AUD-LVL
␠
stage, channel, volume
␍␊
Parameters
stage
-
‘IN, ’OUT’ or numeric value of present audio processing stage
For example: ‘1’ for input level, ‘2’ for output
channel
- input or output number
volume
- audio parameter in Kramer units, minus sign precedes negative values.
++ increase current value,
-- decrease current value
Response Triggers
Notes