Table 1: Front Panel FC-4002 Format Converter / TBC 

#  Feature 

Function 

POWER

 Switch 

Illuminated switch for turning the unit ON or OFF 

FINE 

Trimmer

 

S

Y

N

C

 

P

H

A

S

E

 

COARSE 

Trimmer

 

 
Adjusts

1

 the sync phase level 

 

FINE 

Trimmer

 

S

C

H

 

COARSE 

Trimmer

 

 
Adjusts

1

 the horizontal-to-subcarrier phase level 

 

Y/C Button

 

Selects the s-Video source for conversion 

CV Button

 

Selects the composite video source for conversion 

RGB/S Button

 

Selects the RGB/S source for conversion 

IN

P

U

S

E

LE

C

TO

R

 

YUV Button

 

Selects the YUV source for conversion 

10 

LOCK

 Button

2

 

Disengages the front panel buttons 

11 

FREEZE 

Button 

Freezes the output video 

12 

GENLOCK

 Button

 

Press to enable GENLOCK operation 

Table 2: Rear Panel FC-4002 Format Converter / TBC 

Feature 

Function 

13 

LOOP

 BNC Connector 

Connects to the next Genlocked unit 

14 

SYNC

 BNC Connector 

Connects to the Genlock source 

15 

Term Button

 

Press to terminate the Genlock source (75 ) or release for looping

3

 

16 

CV

 BNC Connector 

Connects to the composite video source 

17 

Y/C

 4p Connector 

Connects to the s-Video (Y/C) source 

18 

G/Y

 BNC Connector 

19 

R/R-Y

 BNC Connector 

20 

SYNC

 BNC Connector

 

21 

IN

P

U

TS

 

B/B-Y BNC 

Connector

 

Connects to the RGB (connect all 3 connectors: 

R

/R-Y, 

G

/Y, and 

B

/B-Y), 

or YUV (connect all 3 connectors: R/

R-Y

, G/

Y

, and B/

B-Y

), 

or RGBS (connect all 4 connectors: 

R

/R-Y, 

G

/Y, and 

B

/B-Y, and 

SYNC

video source

 

22 

CV/R/R-Y

 BNC Connector 

23 

G/Y

 BNC Connector 

24 

SYNC

 BNC Connector 

25 

O

U

TP

U

TS

 

C/B/B-Y

 BNC Connector 

Connects to the RGB (connect all 3 connectors: CV/

R

/R-Y, 

G

/Y, 

and C/

B

/B-Y),  

or YUV (connect all 3 connectors: CV/R/

R-Y

, G/

Y

, and C/B/

B-Y

), 

or RGBS (connect all 3 connectors: CV/

R

/R-Y, 

G

/Y, and C/

B

/B-Y, 

and SYNC) 

video acceptor

 

26 

SETUP

 Dipswitches 

Dipswitches setup (see section 6.2) 

27 

RS-232

 Port 

Connects to the PC or the Remote Controller 

28  Power Connector with 

Fuse

 

AC connector enabling power supply to the unit 

 

 

 

 

 
                                                        

1 Insert a screwdriver into the small hole and carefully rotate it, trimming the level 
2 Press for about 2 seconds to lock/unlock the panel 
3 Push in to terminate the input. Release when the input extends to another unit 

Summary of Contents for FC-4002

Page 1: ...Kramer Electronics Ltd USER MANUAL Model FC 4002 Format Converter TBC...

Page 2: ...rter TBC 3 Figure 2 Connecting a PC without using a Null modem Adapter 7 Figure 3 Connecting the FC 4002 Format Converter TBC 8 Tables Table 1 Front Panel FC 4002 Format Converter TBC 4 Table 2 Rear P...

Page 3: ...you Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this user manual Use Kramer high performance high resolution c...

Page 4: ...el buttons for input selection CV Y C YUV and RGB S Genlock freeze and panel lock Coarse trimmers and fine trimmers for adjusting the sync phase and the horizontal to subcarrier phase SCH Control via...

Page 5: ...Your FC 4002 Format Converter TBC 3 Figure 1 FC 4002 Format Converter TBC...

Page 6: ...lock source 75 or release for looping 3 16 CV BNC Connector Connects to the composite video source 17 Y C 4p Connector Connects to the s Video Y C source 18 G Y BNC Connector 19 R R Y BNC Connector 20...

Page 7: ...Refer to the appropriate nameplate ratings for information For example for fuse replacement see the value printed on the product label 5 The machine is earthed grounded in a reliable way and is connec...

Page 8: ...3 Connect the four BNC OUTPUT connectors CV R R Y G Y and C B B Y and SYNC to a video acceptor for example a plasma display 4 Connect the LOOP BNC connector to the next FC 4002 Genlocked unit if requi...

Page 9: ...your PC to the RS 232 DB9 rear panel port on the FC 4002 unit as Figure 2 illustrates Figure 2 Connecting a PC without using a Null modem Adapter 6 2 Dipswitch Settings The FC 4002 dipswitch settings...

Page 10: ...IP 5 Dipswitch Set as follows 4 AGC ON for enabling automatic gain control OFF for disabling automatic gain control 5 75 Bar Generator ON for enabling 75 Bar Generator OFF for disabling 75 Bar Generat...

Page 11: ...SCH phase SYNC phase H shift freeze panel lock POWER SOURCE 100 240VAC 50 60Hz 14VA DIMENSIONS 19 inch W 7 inch D 1U H rack mountable WEIGHT 2 6 kg 5 7 lbs approx ACCESSORIES Power cord Null modem Ad...

Page 12: ...the machine or 1 when sending from the machine to the PC Table 8 Instruction Set INSTRUCTION I5 I4 I3 I2 I1 I0 0 Reset 0 0 0 0 0 0 16 Error 0 1 0 0 0 0 32 Read front panel switch data 1 0 0 0 0 0 33...

Page 13: ...version number before the decimal point and EXTENDED DATA is the value following the decimal point For example for version 3 4 the machine replies with DATA 03 hex and EXTENDED DATA 04 hex FRONT PANEL...

Page 14: ...is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name...

Page 15: ...or the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions commen...

Reviews: