background image

KRAMER:  SIMPLE CREATIVE TECHNOLOGY

 

Communication Protocol 

  

10 

Table 7: Structure of the Protocol 

MSB 

 

 

LSB 

 

 

INSTRUCTION  

TO PC 

I5 

I4 

I3 

I2 

I1 

I0 

1st byte 
 
 

DATA 

D6 

D5 

D4 

D3 

D2 

D1 

D0 

2nd byte 
 

 

EXTENDED DATA 

E6 

E5 

E4 

E3 

E2 

E1 

E0 

3rd byte 
 

 

MSB’s 

ADDR 

E7 

D7 

4th byte 

 

Note that the MSB’s of the DATA (D7) and the EXTENDED DATA (E7) are in the fourth byte. 

 

Terminology: 

TO PC is the “DESTINATION BIT” 
I4..I0 is the “INSTRUCTION” 
D7..D0 is the “DATA” 
E7..E0 is the “EXTENDED DATA” 

 

The destination bit, TO PC, is 0 when sending from the PC to the machine, or 1 when sending from the machine to the PC. 

Table 8: Instruction Set 

INSTRUCTION 

I5 

I4 

I3 

I2 

I1 

I0 

Reset 

16 

Error  

32 

Read front-panel switch data 

33 

Write front-panel switch data 

61 

Identify machine 

 

DESCRIPTION OF INSTRUCTIONS 

 

INSTRUCTION 0 – RESET

 

DATA=0: initialize the machine. 

When the machine is initialized, it will send the RESET code (DATA = 0). If the machine receives this code, it will reset to its 

“power-up” state. 

DATA=1: configure the machine to its factory default state. 

When the machine receives this code, all programmable parameters will be reset to their factory-default values. 

EXTENDED DATA - set as 0. 

 

INSTRUCTION 16 – ERROR

 

If the machine receives an invalid instruction, it replies by sending this error code. 

 

Summary of Contents for FC-4002

Page 1: ...Kramer Electronics Ltd USER MANUAL Model FC 4002 Format Converter TBC...

Page 2: ...rter TBC 3 Figure 2 Connecting a PC without using a Null modem Adapter 7 Figure 3 Connecting the FC 4002 Format Converter TBC 8 Tables Table 1 Front Panel FC 4002 Format Converter TBC 4 Table 2 Rear P...

Page 3: ...you Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this user manual Use Kramer high performance high resolution c...

Page 4: ...el buttons for input selection CV Y C YUV and RGB S Genlock freeze and panel lock Coarse trimmers and fine trimmers for adjusting the sync phase and the horizontal to subcarrier phase SCH Control via...

Page 5: ...Your FC 4002 Format Converter TBC 3 Figure 1 FC 4002 Format Converter TBC...

Page 6: ...lock source 75 or release for looping 3 16 CV BNC Connector Connects to the composite video source 17 Y C 4p Connector Connects to the s Video Y C source 18 G Y BNC Connector 19 R R Y BNC Connector 20...

Page 7: ...Refer to the appropriate nameplate ratings for information For example for fuse replacement see the value printed on the product label 5 The machine is earthed grounded in a reliable way and is connec...

Page 8: ...3 Connect the four BNC OUTPUT connectors CV R R Y G Y and C B B Y and SYNC to a video acceptor for example a plasma display 4 Connect the LOOP BNC connector to the next FC 4002 Genlocked unit if requi...

Page 9: ...your PC to the RS 232 DB9 rear panel port on the FC 4002 unit as Figure 2 illustrates Figure 2 Connecting a PC without using a Null modem Adapter 6 2 Dipswitch Settings The FC 4002 dipswitch settings...

Page 10: ...IP 5 Dipswitch Set as follows 4 AGC ON for enabling automatic gain control OFF for disabling automatic gain control 5 75 Bar Generator ON for enabling 75 Bar Generator OFF for disabling 75 Bar Generat...

Page 11: ...SCH phase SYNC phase H shift freeze panel lock POWER SOURCE 100 240VAC 50 60Hz 14VA DIMENSIONS 19 inch W 7 inch D 1U H rack mountable WEIGHT 2 6 kg 5 7 lbs approx ACCESSORIES Power cord Null modem Ad...

Page 12: ...the machine or 1 when sending from the machine to the PC Table 8 Instruction Set INSTRUCTION I5 I4 I3 I2 I1 I0 0 Reset 0 0 0 0 0 0 16 Error 0 1 0 0 0 0 32 Read front panel switch data 1 0 0 0 0 0 33...

Page 13: ...version number before the decimal point and EXTENDED DATA is the value following the decimal point For example for version 3 4 the machine replies with DATA 03 hex and EXTENDED DATA 04 hex FRONT PANEL...

Page 14: ...is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name...

Page 15: ...or the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions commen...

Reviews: