background image

Communication Protocol 

 

 

11

INSTRUCTION 32 – READ FRONT-PANEL SWITCH DATA

 

When sending to machine:- DATA = front-panel switch number; EXTENDED DATA - set as 0. 

When replying:- DATA = front-panel switch number; EXTENDED DATA = front-panel switch value + 128. 

The PC sends this instruction to the machine. The machine replies by sending back a value which relates to that switch.  

 

INSTRUCTION 33 – WRITE FRONT-PANEL SWITCH DATA

 

DATA = front-panel switch number; EXTENDED DATA = front-panel switch value.  

- The PC sends a value directly to the machine. If valid, the machine implements this new value, and replies by sending the 

same data back to the PC. Note that the addressed front-panel switch does not need to be pressed in order to change its value 

via RS-232. 

- If the “+” or “-” button is pressed on the machine, resulting in a change in a switch value, then this switch number and value 

is sent to the PC. 

 

INSTRUCTION 61 – IDENTIFY MACHINE

 

For sending, DATA = 3 to request software version number. EXTENDED DATA - set to 0. 

The PC sends this instruction to the machine. The machine replies as follows: 

If the software version is requested, the machine replies with DATA as the version number before the decimal 

point, and EXTENDED DATA is the value following the decimal point. For example, for version 3.4, the machine replies 

with DATA = 03 (hex), and EXTENDED DATA = 04 (hex). 

 

FRONT-PANEL SWITCH DATA

 

 

INPUT SWITCH 

The value of the switch data for the INPUT switch is defined as: 

0 = CV 

1 = YC 

2 = YUV 

3 = RGB/S 

4 = SDI (

FC-4001

 only) 

 

GENLOCK SWITCH 

The value of the switch data for the GENLOCK switch is defined as: 

1 = Machine is in Genlock mode. 

0 = Machine is not in Genlock mode. 

 

GENLOCK_STAT SWITCH

 (inner switch, not on front panel) 

The value of the switch data for the GENLOCK_STAT switch is defined, when GENLOCK is ON, as: 

1 = Machine is Genlocked to input. 

0 = Machine is not Genlocked to input. 

 

PANEL_LOCK SWITCH

 

The value of the switch data for the PANEL_LOCK switch is defined as: 

1 = Machine's front panel is locked. 

0 = Machine's front panel isn't locked. 

 

FREEZE_SWITCH

 

The value of the switch data for the FREEZE switch is defined as: 

1 = Freeze is ON. 

0 = Freeze is OFF. 

 

Table 9 contains the front-panel switch numbers, as defined for this protocol, and indicates the information which may be read 

(status, data) on each switch: 

Table 9: Front-Panel Switch Numbers 

SWITCH 

D4 

D3 

D2 

D1 

D0 

STATUS  DATA 

Select Input Format  0 

NO 

YES 

Genlock 

YES 

NO 

Panel lock 

YES 

NO 

Freeze 

YES 

NO 

Genlock Stat 

YES 

NO 

 

Summary of Contents for FC-4002

Page 1: ...Kramer Electronics Ltd USER MANUAL Model FC 4002 Format Converter TBC...

Page 2: ...rter TBC 3 Figure 2 Connecting a PC without using a Null modem Adapter 7 Figure 3 Connecting the FC 4002 Format Converter TBC 8 Tables Table 1 Front Panel FC 4002 Format Converter TBC 4 Table 2 Rear P...

Page 3: ...you Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this user manual Use Kramer high performance high resolution c...

Page 4: ...el buttons for input selection CV Y C YUV and RGB S Genlock freeze and panel lock Coarse trimmers and fine trimmers for adjusting the sync phase and the horizontal to subcarrier phase SCH Control via...

Page 5: ...Your FC 4002 Format Converter TBC 3 Figure 1 FC 4002 Format Converter TBC...

Page 6: ...lock source 75 or release for looping 3 16 CV BNC Connector Connects to the composite video source 17 Y C 4p Connector Connects to the s Video Y C source 18 G Y BNC Connector 19 R R Y BNC Connector 20...

Page 7: ...Refer to the appropriate nameplate ratings for information For example for fuse replacement see the value printed on the product label 5 The machine is earthed grounded in a reliable way and is connec...

Page 8: ...3 Connect the four BNC OUTPUT connectors CV R R Y G Y and C B B Y and SYNC to a video acceptor for example a plasma display 4 Connect the LOOP BNC connector to the next FC 4002 Genlocked unit if requi...

Page 9: ...your PC to the RS 232 DB9 rear panel port on the FC 4002 unit as Figure 2 illustrates Figure 2 Connecting a PC without using a Null modem Adapter 6 2 Dipswitch Settings The FC 4002 dipswitch settings...

Page 10: ...IP 5 Dipswitch Set as follows 4 AGC ON for enabling automatic gain control OFF for disabling automatic gain control 5 75 Bar Generator ON for enabling 75 Bar Generator OFF for disabling 75 Bar Generat...

Page 11: ...SCH phase SYNC phase H shift freeze panel lock POWER SOURCE 100 240VAC 50 60Hz 14VA DIMENSIONS 19 inch W 7 inch D 1U H rack mountable WEIGHT 2 6 kg 5 7 lbs approx ACCESSORIES Power cord Null modem Ad...

Page 12: ...the machine or 1 when sending from the machine to the PC Table 8 Instruction Set INSTRUCTION I5 I4 I3 I2 I1 I0 0 Reset 0 0 0 0 0 0 16 Error 0 1 0 0 0 0 32 Read front panel switch data 1 0 0 0 0 0 33...

Page 13: ...version number before the decimal point and EXTENDED DATA is the value following the decimal point For example for version 3 4 the machine replies with DATA 03 hex and EXTENDED DATA 04 hex FRONT PANEL...

Page 14: ...is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name...

Page 15: ...or the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions commen...

Reviews: