Kramer Electronics Ltd.
AFM-20DSP
– Defining AEC Settings
51
Users can select to pass the signal through the input directly to the Matrix, or to first pass the
data to the Auto Mixer and then to the Matrix.
To send input data directly to the Matrix:
1. From the Navigate List, select
DSP
.
2. For each port number, select
Direct
.
The input is now set to go directly to the Matrix.
To send input to the Auto Mixer and then to the Matrix:
1. From the Navigate List, select
DSP
.
2. For each port, select the first
Auto Mixer
icon.
3. Select the second
Auto Mixer
icon.
Figure 61: Auto Mixer option selected
As shown in this screenshot the input first goes to the Auto Mixer and then to the Matrix:
Figure 62: Input sent to Auto Mixer before going to the Matrix
The input is now set to enter the Auto Mixer before going to the Matrix.
Gain Sharing Auto Mixer Inputs
Each input includes:
Mute
-100 to 16 dB, 0.01dB steps.
RMS Meter
-80 to 40 dB, 0.1 dB steps.
Auto Gain Meter
-100 to 0 dB, 0.1 dB steps (Shows calculated gain for each channel).
Manual On
Changes the gain from automatic (off) to fixed (on).
Note - While Manual On, the gain for the channel is fixed and does not
impact other channels.