5 Function description
5.3 Assignment pump station - pump
5.3 Assignment pump station - pump
DL3
NE
DL4
NE
DS1
NE
DS3
NE
DS4
NE
1800
15
3200
32
150
5
900
15
1600
32
2300
20
4000
42
240
5
1100
20
2000
40
2900
26
6000
54
320
10
1500
26
3200
32
400
7.5
1800
15
4000
40
500
10
2300
20
6000
54
750
7.5
2900
26
1000
10
1300
13
Tab. 9: Assignment pump station DL/ DS - pump NE
5.4 Reversing valve
If the lever of the reversing valve
6
is in one of the two side positions, the respectively other line of the
station is separated from the fluid circuit so that the strainer of this line can be opened and cleaned. If
the lever is in the centre position, both lines are connected to the fluid circuit. The delivery rate can thus
be increased through parallel operation of the two pumps. If only one pump is being operated, the
second pump can be cut in automatically if the delivery rate or the pressure drops at the active line. In
order to ensure a uniform distribution of the operating hours, an interval-controlled automatic switch-
over between the two pumps is also possible in this valve position. The non-return valves ensure that
the respective pump that is stopped does not begin to rotate backwards.
5.5 Overflow valve
1 2
4
5
8
7
6
9
3
Fig. 6: Overflow valve
1
Screw plug
2
Adjusting screw
3
Pressure spring
4
Seal ring
5
Reversing valve lever
6
Suction-side connection
7
Valve ball
8
Control block
9
Pressure-side connection
The overflow valve is integrated in the control block and ensures that very high pressures that could
result in housing parts bursting do not arise.
The overflow valve is purely there as a safety element for the pumps and should not be used for control
or regulation purposes such as maintaining pressure. If the valve is kept open for too long under ad-
verse operating conditions (high differential pressures and/or low viscosities) it will only take a few
minutes for the overflow valve and the valve seating to become damaged. As a result, the overflow
valve will leak permanently and there will be a corresponding reduction in the delivery rate. In addition
to this, circulation through the overflow valve for too long results in excess heating of the pump. This
reduces viscosity and can ultimately lead to pump failure.
It therefore has to be ensured at the system by a safety valve that the maximum operating overpres-
sure always lies under the opening pressure of the overflow valve.
Notice
The opening pressure of the overflow valve is set to 110% of the differential pressure in the factory.
The overflow valve is accessible through a screw plug
1
and can be adjusted from the outside
Operating instructions
OID 06en-GB Edition 2019-11
11