12 Servicing
12.5 Replacing the pump
12.5 Replacing the pump
Personnel qualification:
o
Fitter
o
Electrician
Personal protective equipment:
o
Work clothing
o
Face protection
o
Protective gloves
Aids:
o
Hoisting equipment
DANGER
Risk of death resulting from electric shock.
► Ensure that the electrical power supply is de-energized and is secured against being switched
back on.
► Before commissioning ensure correct grounding and equipotential bonding.
► Observe the operating instructions of the electrical components.
WARNING
Risk of injury through emitted pumped liquid.
Pumped liquids can be hot, poisonous, combustible and caustic.
► Wear personal protective clothing during all the work. Ensure face protection.
► Collect any discharging pumped liquid safely and dispose of it in an environmentally compatible
manner in accordance with the applicable local regulations.
► If work on the blocked part of the pump station takes longer, monitor the filling level of the strainer
housing and catch the leakage.
WARNING
Risk of injury through emitted pumped liquid when working on the pump station without previ-
ous pressure relief.
► Open the screw plug of the vent hole by a max. of 2 rotations in order to reduce the internal pres-
sure in the housing.
Requirement:
ü
Pump unit disconnected from the electrical power supply, deenergized and secured against being
switched back on
ü
Coupling removed
2
1
3
1.
Pull the cartridge housing
1
exactly vertically via the stud screws
2
from the housing
3
.
2.
Clean all the sealing surfaces thoroughly.
3.
Insert the new pump into the housing via stud screws.
4.
Installing the coupling
Ä
Operating instructions
OID 06en-GB Edition 2019-11
33