8 Installation, removal
8.4 Removing the pump station
IN
OUT
2
1
3
Fig. 8: Mounting the pump station
1
Suction-side connection
2
Pressure-side connection
3
Fastening element
Requirement:
ü
Pump station connections protected against soiling, for example by using the protective cover
mounted in the factory
1.
Bring the pump station into the installation position. Take the flow direction into consideration.
2.
Fasten the pump station with fastening elements
3
securely on the underground.
3.
After the connecting work clean the pipe system thoroughly
8.4 Removing the pump station
Personnel qualification:
o
Transport personnel
o
Fitter
o
Electrician
Personal protective equipment:
o
Work clothing
o
Protective helmet
o
Protective gloves
o
Safety boots
Aids:
o
Mobile crane, forklift, hoisting equipment
o
Collection tank
DANGER
Risk of death resulting from electric shock.
► Ensure that the electrical power supply is de-energized and is secured against being switched
back on.
► Observe the operating instructions of the electrical components.
DANGER
Risk of death through emitted pumped liquid.
Pumped liquids can be hot, poisonous, combustible and caustic and can spray out under high pres-
sure.
► Wear personal protective clothing during all the work. Ensure face protection.
► Before beginning work, let the pump station cool down to the ambient temperature.
► Ensure that the pump station is depressurized.
► Collect any discharging pumped liquid safely and dispose of it in an environmentally compatible
manner in accordance with the applicable local regulations.