KPWL-0300 User's Manual
24
Advanced
Item
Description
Values that can be
set
Default value
AMPDU
You can specify whether to link the frames through
A-MPDU (link including MAC header).
ON (performed) / OFF
(not performed)
ON
AMSDU
You can specify whether to link the frames through
A-MSDU (link after MAC header only).
ON (performed) / OFF
(not performed)
ON
DTIM Period
You can specify the interval for sending DTIM (Delivery
Traffic Indication Message: notification that data is being
transmitted).
1 to 255 alphanumeric
characters
1
Tx Power
You can decrease the signal connectability (make the
area smaller) from the access point by limiting the
transmission output.
10% to 100%
100%
Beacon Interval
You can set the beacon interval. Shortening the beacon
interval makes it easier for clients to detect access points,
but reduces the transmission efficiency.
40 to 1000 ms
100
Security
Item
Description
Values that can be
set
Default value
SSID
Specify the SSID for the wireless security setting.
Broadcast SSID
You can specify whether to use stealth mode, in which
beacon notification for SSID (ESSID) is not done. If you
specify disabled, then beacon notification is not done and
the stealth mode functions.
Enable, Disable
Enable
Wireless Client Isolation
Set whether or not it is possible to communicate between
wireless clients.
•
Disable: It is possible to communicate between
terminals over SSID.
•
STA Separator: Allows communications between
wireless clients.
•
SSID Separator: Turns off communications between
SSIDs.
Disable
STA Separator, SSID
Separator
Disable
Authentication Method
You can select the type of network authentication.
No Authentication
WEP
IEEE802.1x/EAP
WPA-PSK
WPA-EAP
No Authentication
Additional
Authentication
You can set whether to use MAC address filters or MAC
RADIUS authentication.
*If you selected WPA-EAP for "Authentication Method",
you cannot select MAC RADIUS authentication.
No additional
authentication
MAC address filters
MAC RADIUS
authentication
No additional
authentication
Key Length
*Appears if you selected WEP or IEEE802.1x/EAP for
"Authentication Method".
Specify the length of the key for doing encryption.
64 bit, 128 bit
64 bit
Key Type
*Appears if you selected WEP for "Authentication
Method".
Specify the type of key for doing encryption.
* Specify ASCII if the key uses half-byte alphanumerics.
Specify Hex if the key uses hexadecimal.
•
For 64 bit:
ASCII (5Characters),
Hex (10Characters)
•
For 128 bit:
ASCII (13Characters),
Hex (26Characters)
•
For 64 bit:
ASCII (5Characters)
•
For 128 bit: