4
Table 2.1, Included Parts and Components
Part Number
Description
CXL-770A
Millivolt Control Board Assembly
700-203
Manual Gas Shut-off Valve
CXL-135
Burner Assembly
CXL2-I900
Firebrick Refractory Set
CXL2-500
Log Package
700-006T
Glass Valance
816-CL1
Colinear Air Duct
CSK-028
Fan Kit (2)-75 CFM
500-CXL
Grill Assembly
2.0
SPECIFICATIONS
2.2
Heating Specifications
Table 2.3, Input Ratings, Gas Pressure, and Orifice Sizes
Fuel
Input BTU/hr. (kW)
Minimum Input
BTU/hr. (kW)
Orifice
Size
Manifold Pressure
(Low)
Manifold Pressure
(High)
Natural Gas
36,000 BTU/h (10.55 kW)
22,000 BTU/h (6.49 kW)
#35
1.6” WC (.40 kPa)
3.5” WC (.87 kPa)
LP Gas
36,500 BTU/h (10.7 kW)
24,000 BTU/h (7.03 kW)
#50
6.4” WC (1.59 kPa)
10” WC (2.49 kPa)
2.3
High Altitude Installations
ATTENTION
USA:
The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines
which state the sea level rated input of Gas Designed Appliances installed at elevations above 2,000 ft. (610 m) is to be reduced
4% for each 1,000 ft. (305 m) above sea level. Refer also to National Fuel Gas Code, ANSI Z223.1 / NFPA 54, local authorities, or
codes which have jurisdiction in your area regarding the de-rate guidelines.
Canada:
When the appliance is installed at elevations above 4,500 ft. (1,372 m), the certified high altitude rating shall be
reduced at the rate of 4% for each additional 1,000 ft. (305 m). Refer also to CSA-B149.1 Natural Gas and Propane Installation
Code, local authorities, or codes which have jurisdiction in your area regarding the de-rate guidelines.
2.1
Components
2.1.1
Additional Components Required
Approved Venting Systems:
Kozy Heat #816-CL Co-Linear Direct Vent System
For use with minimum 6” x 8” I.D. masonry or 7” I.D.
Class A metal chimneys
Includes 12 ft. (3.66 m) of compressed flexible 3” x 3”
co-linear pipes expandable to 35 ft. (10.67 m) and
termination cap.
ICC, Selkirk, Amerivent - American Metal Products,
Simpson Dura-vent
Shrouds:
Part #CK34-2740, 27” x 40” Shroud (1 pc)
Part #CK34-3044, 30” x 44” Shroud (1 pc)
Part #CK34-3346, 33” x 46” Shroud (1 pc)
Custom Shrouds:
Part #CK34-CUS Custom Shroud
Part #CK34-ACUS Arched Custom Shroud
NOTE
Only trim kits supplied by Hussong Mfg. Co., Inc. shall be used in the installation of the appliance.