19
10.0
THERMOSTAT, WALL SWITCH, REMOTE
NOTE
Installation of the thermostat or wall switch should only be performed by a qualified installer.
CAUTION
Do not connect high voltage (115V) wire to the gas valve.
10.2
Thermostat and Wall Switch
1. Run low-voltage wires from the terminals on the gas valve to the desired location of the component (thermostat or wall switch).
2. Attach the appropriate connectors to the wall switch wires or thermostat wires. Connect to top and bottom terminals marked TH
and TP-TH on the gas valve.
Figure 10.3 Thermostat Wiring Diagram
Figure 10.2, Remote Control Wiring Diagram
10.1
Remote Control
Follow instructions included with the remote control.
The insulated cover included with the remote control must be place over the remote receiver to prevent overheating.
If desired, a thermostat, a wall switch, or a remote control assembly may be installed to enable on/off control of the main burner.
Only one of these components may be installed. Follow instructions included with the component.
Figure 10.1, Rocker Switch Wire Locations
It is optional to disable the rocker switch operation of the main burner by
disconnecting the rocker switch wires from the back of the gas valve.
See Figure 10.1.
If the rocker switch wires are not disconnected, the ON/OFF rocker
switch on the millivolt board must be in the OFF position for proper
operation of the thermostat, wall switch, or remote control.
If the rocker switch is ON, the main burner will operate until it is turned
OFF by the rocker switch. These components will not turn the main
burner OFF when it has been turned ON by the rocker switch.
The fireplace insert must be turned ON and OFF by the same method.
For example, if the fireplace insert is turned on by the remote control, it