Operation of control panel
Use the lower knob to select operating mode
[3]:
-
stand-by > heating pump is off, only
frost protection is active,
-
compressor > according to configured
work schedule heat pump maintains
set hot water temperature if the air
temperature intake does not allow to
activate compressor, occasionally the
conditions of starting heat pump will be
verified,
-
comp additional heat source>
according to configured work schedule heat
pump maintains set hot water temperature,
if the air temperature intake will not allow to
activate compressor additional heat source
is activated and occasionally the conditions
of starting heat pump will be verified,
-
comp additional heat source
+ heater > according to configured work
schedule heat pump and external heat
source maintain set hot water temperature,
if the air temperature intake will not allow to
activate compressor heater is activated and
occasionally the conditions of starting heat
pump will be verified,
-
additional heat source > according
to configured work schedule additional
heat source maintains set hot water
temperature,
-
A
turbo > selecting this mode enables
heating water with all available
heat sources until reaching the set
temperature,and returns to the previous
work mode except stand-by mode. In
[1] - display
[2] - preview and settings navigation
dial
[3] - mode dial
2
3
1
9:37 TUE 2.01.2018
9:37 TUE 2.01.2018
17
17
°°
41
41
°°
12.7°
12.7°
Tzad
Tzad
50°
50°
order to activate the mode enter required hot water temperature, then default
temperature of 50°C will be displayed. The temperature level can be corrected
using upper dial and then confirmed by pressing the upper dial. After around 10
seconds of inactivity the level of temperature will be automatically saved.