16
In daily schedule hot water circuit has defined starting time (3) and finishing time (4) of
maintaining selected temperature (5) (from range of 30..60°C). Except set time frames
only frost protection of the storage cylinder will be possible. For circulation circuit within
the schedule there is an adjustment of starting time and finishing time of circulation
pump’s operation. To change the parameters for the daily schedule, select chosen
program number and press navigation dial. Editing field flashes, use the navigation dial
to set the new time frame value (hour and minutes separately) and confirm by pressing
the dial, then move to next field edition that starts flashing. Last editable position is a
command. To save changes select command ‘save’
and press the dial to finish editing.
To delete selected time frame, edit chosen time frame and by pressing the dial go to
command position, select command ‘delete and press the dial.
To add new time frame, select last defined time frame and by pressing the dial go to
command position, select command ‘add’ and press the dial to add new time frame
which by editing can be adjusted to personal preferences (described above). If all five
time frames were used or there is no time break for new period, the command will
not be visible. If there are no defined time frames within daily schedule, after selecting
“new”, 40 C will be set as daily temperature. The daily program will be saved to the heat
pump settings after leaving daily program and pressing the command “SAVE AND EXIT”.
Daily schedule:
DHW PROGRAMME NO1
DHW PROGRAMME NO1
SAVE AND EXIT
SAVE AND EXIT
1 6:20 - 8:00 42°
2 18:30 - 23:00
2 18:30 - 23:00 50°
50°
2
3
4
5
6
1
[1] - selected time period
[2] - no. of time frame according to schedule
(max 5)
[3] - time of starting set temperature
[4] - time of finishing set temperature
[5] - setting DHW temperature
[
6] - command (active when editing):
accept
delete
add