knowledge prevent them from a safe use of the boiler unless they are 
supervised or if they were not instructed on the use of device by a 
person responsible for their safety. 

3.

 

Children should be supervised in order to ensure that they do not play 
with the boiler. 

4.

 

Flammable materials must not be in the minimal distance of 1500 
mm from the boiler when emptying the ash at the boiler. 

5.

 

It is 

disallowed

 to overheat the boiler during its operation. 

6.

 

It is 

not recommended

 to operate the boiler for a long period of time 

at an output lower than 50%. 

7.

 

It is 

disallowed

 usage of flammable liquids for firing the boiler. 

8.

 

When the boiler operates at a lower temperature than of 60 °C the 
retting, or the so called low – temperature rust, of the boiler drum 
may occur that reduces the operating life of the boiler drum. 
Therefore we recommend to operate the boiler at a temperature of   
60 °C or higher. We recommend to install the 3 or 4 way mixing 
valve in order to maintain mentioned temperature in the boiler. 

9.

 

After finishing of the heating period it is necessary to properly clean 
the boiler, smoke stack and chimney. The smoky flap mechanism and 
other movable parts should be covered with graphite grease. 

10.

 

It is necessary to install a pressure-relief valve for maximum 
overpressure of 2 bars and thermomanometer for pressure control. 
The pressure-relief valve must be located directly behind the boiler. 
Any stop valve must not be located between the pressure-relief valve 
and boiler. 

11.

 

The cooling coil must be activated constantly in order to prevent the 
system overheating. 

12.

 

It is recommended to install a buffer tank and pump type group with 
thermostatic mixing valve to the boiler. The capacity of buffer is 55 
liters of water per 1 kW installed boiler power. 

13.

 

During assembly, installation and operation of the appliance it is 
necessary to comply with standards that apply in the relevant country 
of destination. 

14.

 

In order to increase the endurance life of brick chimney the inner 
walls of chimney should be lined with steel. 

 

 

ATTENTION! Failure to observe the installation and 

operating requirements described in this manual voids 
the warranty and shorten an endurance life of boiler.  

 

 

Summary of Contents for Kordi-10S

Page 1: ...allation and operation the country specific requirements and regulations must be observed local construction regulations on the installation air supply and exhaust gas extraction as well as chimney connection regulations and norms concerning the fitting of the heating installation with safety devices 1 1 1 Safety rules for user operation operate the heating boiler at a maximum temperature of 95ºC ...

Page 2: ...ammable materials liquids must not be left in close proximity of the heating boiler Instruct boilers user of the allowed minimum clearances more than 400 mm from surrounding flammable objects DANGER of intoxication or explosion Toxic gases may be discharged when burning waste plastics or liquids Burning of mentioned materials is unallowable Use only the fuels indicated in this manual In case of da...

Page 3: ...ive Class B materials For easily combustible materials Class C F which quickly burn and burn themselves even after removal of ignition source such as paper cardboard asphalt and tar paper wood and wood fiber boards plastics floor coverings the safe distance has to be doubled to 400 mm EN 13 501 1 classification of materials and products Class A Non combustible Granite sandstone concrete bricks cer...

Page 4: ...ing the boiler platform over 100 mm at sides and 500 mm at front It is also recommended to put a basalt cardboard soaked with clay mortar under the steel sheet Handling space of minimum 1500 mm in front of the boiler must be maintained If the boiler is installed in a basement or cellar we recommend placing it on a foundation of minimum 50 mm height In order to maintain space for access to the back...

Page 5: ...l Total dimensions Height mm Width mm Depth mm 695 517 810 Maximum fuel capacity lts 19 0 1 s r a e y d o i r e p e c n a r u d n E Weight kg 117 Table 1 Technical data of the boilers 2 1 Fuels Combustion chamber can utilize only natural and untreated wood or coal Pressed fuels and briquettes containing only wood may also be used Log length should be up to 300 mm To reach the rated power of the he...

Page 6: ...ting screw 12 Cooking zone 4 Stoker door 13 Thermomanometer mounting place G 5 Draft regulator components can be ordered separately 14 Chimney 6 Hot water supply branch pipe 15 Restrictor 7 Returnable water branch pipe 16 Ignition flap 8 Pressure relief valve mounting place G 17 Waste gas flue shutter 9 Ignition controller 18 Temperature sensor mounting place inner D 20mm ...

Page 7: ...e chimney through the central vertical stack ATTENTION When operating the boiler always keep the waste gas flue shutter 17 in such position that shown above Remove the waste gas flue shutter only for cleaning vertical stacks 3 TRANSPORTATION AND DELIVERY OF THE BOILER 3 1 Transportation and storage demands The transportation of the heating boiler should be carried out in its factory packaging at a...

Page 8: ... contact your supplier 4 INSTALLATION OF THE HEATING BOILER CAUTION The assembly and installation of the boiler should be performed according your country requirements and heating project documentation by a service organization authorized for performing of this operation Always observe building supervision instructions in particular existing Ordinance on combustion devices and storage of combustio...

Page 9: ...hrough a thermostatic valve In a case of overheating the thermostatic valve feeds in cold water that passes through the cooling coil and absorbs the heat in the boiler The draining valve discharges it into the sewage system This device ensures safe evacuation of the excess heat without the need of user s presence The cooling coil guarantees that the water in the boiler will not exceed the maximum ...

Page 10: ...ditions The proper functioning of the chimney requires appropriate sizing since the draught it produces affects combustion boilers output and life span The chimney diameter must not be smaller than the flue outlet of the boiler no less than 127 mm Only heating specialist must calculate the precise sizing of a chimney The flue outlet must be properly sealed to avoid gas leak Avoid using elbow joint...

Page 11: ...ces oil and chemically aggressive substances The water hardness must not exceed the required parameters Hardness 1 mmol l Ca 0 3 mmol l Fe Mn 0 3 mg l total recommended value Even multiplying heating of the water with higher hardness does not prevent from excluding of soils on the boiler drum walls The precipitation of 1 mm of limestone reduces the heat transfer from metal to water up to 10 ATTENT...

Page 12: ... When ignition the boiler for the first time a condensate is formed which is later drained it is not a fault 5 2 1 Performance of fire in the boiler Set the ignition controller in Open position 5 2 2 Setting the boiler on the necessary operating temperature The recommended temperature of the output water is 60 80 C 5 2 3 Operating of the boiler in the operating condition according to the competent...

Page 13: ...according to the sort of used fuel because a full ashtray prevents the right distribution of the burning air under the fuel and causes unequal burning process of fuel CAUTION The ash is needed to be put away into the fireproof container with a cover It is necessary to use protective facilitations and to pay attention to personal safety while operating If there is a settlement of tar silt on the wa...

Page 14: ...he boiler 9 After finishing of the heating period it is necessary to properly clean the boiler smoke stack and chimney The smoky flap mechanism and other movable parts should be covered with graphite grease 10 It is necessary to install a pressure relief valve for maximum overpressure of 2 bars and thermomanometer for pressure control The pressure relief valve must be located directly behind the b...

Page 15: ... boiler operation is not valid The user is obliged to perform a regular control of the boiler Failing to keep the mentioned instructions the warrants provided by the producer are not granted Each notice of defect must be made immediately after its finding always in written form and by a phone agreement The manufacturer grants the right for changes performed within the frame of product innovation t...

Page 16: ...16 ...

Page 17: ...by a contractual service organization has not shown out any defect at the heat test has received Operation and installation manual with a proper filled in Warranty card has been introduced to the boiler operation and maintenance rules for using mastered ________________________________________ Users signature ___________________ Production date ___________________ Stamp of the producer ___________...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...20 ...

Reviews: