Product Description
20
PxV414 – 4U Platform User Manual
Versions of the Power Supply Unit
The power supply unit is placed on the rear side of PxV414 – 4U Platform.
Each PxV414 – 4U Platform can be equipped optionally depending on the power
supply unit (PSU) with an AC-PSU or a DC-PSU.
For information about the power supply unit and the supply voltage of your
system, refer to the type label attached on the right side of the unit.
System
Version
Integrated
PSU
Input
PxV414-A
AC PSU
100 – 240 VAC
50 – 60 Hz
max. 3.6 A
PxV414-C
DC PSU
-48 to -60VDC
max. 8.0 A
PxV414-F
DC PSU
24 to 32 VDC
max. 14 A
Safety instruction for devices with -48 V DC-PSU:
In devices with -48 V DC PSU (PxV414-C) it is not allowed to
remove or to bridgeover the installed ATX-connector with the
Kontron-ATX cable extension (T10 A fuse integrated in the
3.3 V circuit).
Safety instruction for the DC-PSUs:
For DC power supplies please observe that the supply circuit
must withstand loads minimum 50A for the 24V power supply and