Introduction
CP6000
Page 1 - 18
© 2005 Kontron Modular Computers GmbH
ID 27942, Rev. 05
2794
2.05.UG.VC.051020/17275
8
P R E L I M I N A R Y
1.8
Standards
This
Kontron Modular Computers’
product complies with the requirements of the following
standards:
Table 1-3: Standards
TYPE
ASPECT
STANDARD
REMARKS
CE
Emission
EN55022
EN61000-6-3
--
Immission
EN55024
EN61000-6-2
--
Electrical Safety
EN60950-1
--
Mechanical
Mechanical Dimensions
IEEE 1101.10
--
Environmental
Vibration
(sinusoidal)
IEC60068-2-6
Ruggedized version test parameters:
• 10-300 (Hz) frequency range
• 2 (g) accelleration
• 1 (oct/min) sweep rate
• 10 cycles/axis
• 3 axis
Vibration, broad-band
random (digital control)
and guidance
IEC60068-2-64
Ruggedized version test parameters:
• 20-500Hz, 0.05 (g²/Hz) PSD
• 500-2000Hz, 0.005 (g²/Hz) PSD
• 3.5 (g RMS) acceleration
• 30 (min) test time/axis
• 3 axis
Bump
IEC60068-2-29
Ruggedized version test parameters:
• 15 (g) acceleration
• 11 (ms) pulse duration
• 500 bumps per direction
• 6 directions
• 1 (s) recovery time
Shock
IEC60068-2-27
Ruggedized version test parameters:
• 30 (g) acceleration
• 9 (ms) pulse duration
• 3 shocks per direction
• 6 directions
• 5 (s) recovery time
Climatic Humidity
IEC60068-2-78
93% RH at 40 °C, non-condensing
WEEE
Directive 2002/96/EC
Waste electrical and electronic equip-
ment
RoHS
Directive 2002/95/EC
Restriction of the use of certain hazard-
ous substances in electrical and elec-
tronic equipment
Note ...
The values in the above table are valid for boards which are ordered with the
ruggedized service. For more information please contact your local Kontron
office.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com