Configuration
AM4100
Page 4 - 14
ID 36126, Rev. 2.0
P R E L I M I N A R Y
Table 4-15: Watchdog Timer Control Register
REGISTER NAME
WATCHDOG TIMER CONTROL REGISTER
ADDRESS
0xEC00_0282
BIT
NAME
DESCRIPTION
RESET
VALUE
ACCESS
7
WTE
Watchdog timer expired status bit:
0 = Watchdog Timer has not expired
1 = Watchdog Timer has expired.
Writing a ’1’ to this bit resets it to 0.
0
R
6-5
WMD
Watchdog Mode:
00 = Timer only mode
01 = Reset mode
10 = Interrupt mode
11 = Cascaded mode (dual-stage mode)
00
R/W
4
WEN/WTR Watchdog enable / Watchdog trigger control bit:
0 = Watchdog Timer has not been enabled
Prior to the Watchdog being enabled, this bit is known as WEN.
After the Watchdog is enabled, it is known as WTR. Once the
Watchdog Timer has been enabled, this bit cannot be reset to 0.
As long as the Watchdog Timer is enabled, it will indicate a ’1’.
1 = Watchdog Timer is enabled
Writing a ’1’ to this bit causes the Watchdog to be retriggered to
the timer value indicated by bits WTM[3:0].
0
R/W
3-0
WTM
Watchdog timeout settings:
0000 = 0.125 s
0001 = 0.25 s
0010 = 0.5 s
0011 = 1 s
0100 = 2 s
0101 = 4 s
0110 = 8 s
0111 = 16 s
1000 = 32 s
1001 = 64 s
1010 = 128 s
1011 = 256 s
1100 = reserved
1101 = reserved
1110 = reserved
1111 = reserved
The nominal timeout period is 5% longer than the above-stated val-
ues.
0000
R/W
Summary of Contents for AM4100
Page 19: ...AM4100 Introduction ID 36126 Rev 2 0 Page 1 1 Introduction Chapter 1 1 P R E L I M I N A R Y...
Page 57: ...AM4100 Installation ID 36126 Rev 2 0 Page 3 1 Installation Chapter 1 3 P R E L I M I N A R Y...
Page 65: ...AM4100 Configuration ID 36126 Rev 2 0 Page 4 1 Configuration Chapter 1 4 P R E L I M I N A R Y...
Page 89: ...AM4100 NetBootLoader ID 36126 Rev 2 0 Page 5 1 NetBootLoader Chapter 1 5 P R E L I M I N A R Y...