Thermal Considerations
AM4100
Page 7 - 8
ID 36126, Rev. 2.0
P R E L I M I N A R Y
7.3.3
Airflow Impedance
In order to determine the cooling requirements of the AM4100, the airflow impedance of a Mid-
size and a Full-size AM4100 module has been determined via simulation. No card guides or
struts have been used for the simulations because the resulting airflow impedance depends on
individual configuration of the AMC carrier or MicroTCA system.
The following figure shows the impedance curves of a Mid-size and a Full-size AM4100 mod-
ule.
Figure 7-6: Mid-Size and Full-Size AM4100 Impedance Curves
The following table indicates the pressure drop at 10, 20, 30, and 40 CFM volumetric flow rates.
Table 7-1:
Pressure Drop vs. Airflow Data
VOLUMETRIC
FLOW RATE [CFM]
PRESSURE DROP [inches H2O]
MID-SIZE
MID-SIZE EMPTY
FULL-SIZE
FULL-SIZE EMPTY
10
0.007
0.004
0.012
0.005
20
0.023
0.013
0.037
0.015
30
0.045
0.025
0.074
0.030
40
0.075
0.041
0.123
0.050