36
454200/A
Troubleshooting
When dealing with wireless catch monitoring sensors you may experience some bad
readings, or no readings at all. There are some checkings you can do before calling
the support department.
To do some of these tests you may need:
• One or several PX MultiSensor Chargers
• PX Configurator cable
• Multimeter
• A computer with the TV80 program installed.
Symptom
Probable cause
What to do
Corroded water switch.
Inspection and replacement of the brass
screw, page 26
Dirty charger sockets.
Cleaning the sensor charger sockets,
page 24
Sensor cannot
be activated
Flat battery.
Charging the sensor battery, page 27
Checking if the sensor charges properly,
page 29
Defective PX
MultiSensor Charger
Measuring the output voltages from the PX
MultiSensor Charger, page 30
Sensor does not
take charge
Dirty charger sockets.
Cleaning the sensor charger sockets,
page 24
Simrad PX MultiSensor Mk2 Instruction Manual
Summary of Contents for Simrad PX MultiSensor Mk2
Page 1: ...kongsberg com simrad Simrad PX MULTISENSOR Mk2 INSTRUCTION MANUAL...
Page 2: ......
Page 6: ...4 454200 A Simrad PX MultiSensor Mk2...
Page 41: ......
Page 42: ...2021 Kongsberg Maritime...