454200/A
31
Note
The
Spectrum
dialog box can only be used with SR type receiver units:
• SR15
• SR70
Procedure
1
On the processor unit desktop, double-click the TV80 icon to start the program.
2
Open the
Setup
menu.
3
On the
Setup
menu, select
Spectrum
to open the dialog box.
4
Observe the graph in the
Spectrum
dialog box.
5
Identify if the pulses from your sensor appear in the expected frequencies.
Simrad catch monitoring sensors communicate on a frequency range from 40 to
50 kHz.
6
Change the sensor channel if you find some interferences within your frequency
range.
Related topics
Frequencies and channels, page 38
Troubleshooting, page 36
Use and maintenance, page 23