38
No.
Description
Remedy
00
Internal error channel 1
Unplug power cord and
contact the customer service.
01
Internal error channel 2
02
Internal error channel 3
12
Defect channel 1
Unplug the control unit.
Fix the external short circuit or
plug in the correct motor to the
motor socket that shows the error.
Start the control unit again.
13
Defect channel 2
14
Defect channel 3
24
Overcurrent motor M1
Remove jammed objects from the
driving area.
Desk might be overloaded
remove load from desktop.
Contact customer service.
25
Overcurrent motor M2
26
Overcurrent motor M3
48
Overcurrent motor group 1
49
Overcurrent motor group 2
60
Collision protection
62
Overcurrent control unit
Cause
Remedy
There is an internal fault in the
control unit.
Proceed as indicated in the
following error list.
Cause
Remedy
The control unit is fitted with over
-
heating protection. Overheating has
caused it to stop the control unit.
Wait until the control unit has
cooled down and HOT is no longer
displayed. The control unit is then
operational again.
Error messages on the handswitch display
The display reads HOT.
The display reads E + an error code.
Summary of Contents for TALO.S Konferenz
Page 2: ......
Page 4: ...1...
Page 8: ...5 4a Tischplatte montieren a b c...
Page 22: ...19 EG Konformit tserkl rung...
Page 25: ...22...
Page 26: ...23...
Page 30: ...27 4a Fitting table top b a c...
Page 44: ...41 Declaration of EU conformity...
Page 47: ...44...