19. Image quality problems
Field Service
V
er. 1.0 Nov. 200
8
116
magicolor 1600W magicolor 1650EN
T
roubleshooting
19.1.5
Low image density
A. Typical faulty images
B. Troubleshooting procedure
ABCDE
ABCDE
ABCDE
ABCDE
ABCDE
4036fs4036c0
Step
Section
Check item
Result
Action
1
Imaging
cartridge
Is the outside dirty?
YES
Clean.
2
Is the contact dirty?
YES
Clean.
3
PH unit
Is the window surface dirty?
YES
Clean.
4
2nd transfer
roller
Is the contact dirty?
YES
Clean.
5
Media
Is the media damp?
YES
Replace the media with new
media that has just been
unwrapped.
6
IDC sensor
board
Is the sensor dirty?
YES
Clean.
7
Have steps 1 to 6 eliminated the
problem?
NO
Replace the toner cartridge.
→
Replace the Imaging car-
tridge.
→
Replace the 2nd transfer roller.
→
Replace the PH unit.
→
Replace the IDC sensor board.
→
Replace the printer control
board.
→
Replace the high voltage unit.
Summary of Contents for magicolor 1600W
Page 3: ...ii Blank Page...
Page 28: ...SERVICE MANUAL 2008 11 Ver 1 0 FIELD SERVICE Main body magicolor 1600W magicolor 1650EN...
Page 174: ...SERVICE MANUAL 2008 11 Ver 1 0 FIELD SERVICE Lower Feeder Unit...
Page 179: ...1 Product specifications Field Service Ver 1 0 Nov 2008 2 Lower Feeder Unit General Blank Page...
Page 193: ...4 Jam display Field Service Ver 1 0 Nov 2008 16 Lower Feeder Unit Troubleshooting Blank Page...
Page 194: ...SERVICE MANUAL 2008 11 Ver 1 0 FIELD SERVICE Duplex Option...
Page 199: ...1 Product specifications Field Service Ver 1 0 Nov 2008 2 Duplex Option General Blank Page...
Page 209: ...3 Other Field Service Ver 1 0 Nov 2008 12 Duplex Option Maintenance Blank Page...