17. Malfunction code
Field Service
V
er. 1.0 Nov. 200
8
108
magicolor 1600W magicolor 1650EN
T
roubleshooting
17.2.9
0500: Fuser warm-up failure
0503: Thermistor resistance failure
17.2.10
0502: Thermistor open-circuit failure
0510: Abnormally low fuser temperature
0520: Abnormally high fuser temperature
Relevant electrical parts
Fuser unit
Printer control board (PRCB)
DC power supply (DCPU)
Step
Action
WIRING DIAGRAM
Control signal
Location (Electrical
component)
1
Change fuser unit.
⎯
⎯
2
For magicolor 1600W:
1.
Main switch is turned ON.
2.
Open the top cover.
3.
Press the following keys in this order.
Rotate Toner key
→
Clear key
→
Clear
key
→
Rotate Toner key.
4.
Main switch is turned OFF/ON.
For magicolor 1650EN:
1.
Main switch is turned ON.
2.
Execute [SER
V
ICE MENU] - [
FUSER
UNLOCK
].
⎯
⎯
3
Change PRCB.
⎯
⎯
4
Change DCPU.
⎯
⎯
Relevant electrical parts
Fuser unit
Printer control board (PRCB)
DC power supply (DCPU)
Step
Action
WIRING DIAGRAM
Control signal
Location (Electrical
component)
1
Check the fuser unit for correct installation
(whether it is secured in position).
⎯
⎯
2
Check the fuser unit, DCPU, and PRCB for
proper connection and correct as neces-
sary.
⎯
⎯
3
Change fuser unit.
⎯
⎯
4
Change PRCB.
⎯
⎯
5
Change DCPU.
⎯
⎯
Summary of Contents for magicolor 1600W
Page 3: ...ii Blank Page...
Page 28: ...SERVICE MANUAL 2008 11 Ver 1 0 FIELD SERVICE Main body magicolor 1600W magicolor 1650EN...
Page 174: ...SERVICE MANUAL 2008 11 Ver 1 0 FIELD SERVICE Lower Feeder Unit...
Page 179: ...1 Product specifications Field Service Ver 1 0 Nov 2008 2 Lower Feeder Unit General Blank Page...
Page 193: ...4 Jam display Field Service Ver 1 0 Nov 2008 16 Lower Feeder Unit Troubleshooting Blank Page...
Page 194: ...SERVICE MANUAL 2008 11 Ver 1 0 FIELD SERVICE Duplex Option...
Page 199: ...1 Product specifications Field Service Ver 1 0 Nov 2008 2 Duplex Option General Blank Page...
Page 209: ...3 Other Field Service Ver 1 0 Nov 2008 12 Duplex Option Maintenance Blank Page...