Ch.3 Sequence of Examination
< 37 >
REGIUS Console CS-3 OPERATION MANUAL Ver. 1.10 2005.2
3
Position the reader device to match the patient.
• If it is necessary to alter size, angle or position,
use the panel switches on the reader device or
touch the image display field on the CS-3
Operation Unit to select them on the detailed data
selection screen.
• For details of operation of the reader device, refer
to the reader device operation manual.
4
Depress the exposure button on the X-ray gener-
ator.
• The image read by the reader will be displayed in
the image display field.
• The S-value of the image read will be displayed
below the image display field.
• The green frame will move to the next order on the
order list.
5
Repeat steps
1
~
4
to execute exposure for
each of the orders on the order list.
Whenever the examina-
tion is started and the
device is switched to
another device, an era-
sure will be carried out.
In order to carry out the
examination smoothly,
it is recommended that
order selection be
made prior to position-
ing the patient for expo-
sure when using the
upright position reader.
Automatic Confirmation Function
In cases where there is an automatic confirmation function, after a cer-
tain time has elapsed from reading the image with a green frame
around the order, the confirmation process will be judged to be com-
pleted and the image will be output.
This function is not available in the examination check screen (multiple-
image format).
• The [OK] button displays time remaining (secs.) until the order
is confirmed automatically.
p.45, 46
Image Output
[Single-Image Format]
p.95
Patient Data
Amendment Screen
p.98
Body Part/ Parameter
Selection Screen
p.103
Detailed Data
Setting Screen
(Image Processing)
p.111
Detailed Data
Setting Screen
(Print Format)
p.118
Detailed Data
Setting Screen
(Overlay)
Following this screen:
Select the target
order from the
order list.
Amending patient data
Amending exposure parameters/
Adding or deleting the order
Amending image processing
Select the target
order from the
order list.
Select the target
order from the
order list.
Amending print format
Amending overlay
Image
Display
Field
Image
Processing
Format
Overlay
Touch
Select the target
order from the order
list.
Outputting the image
Touch
Touch
Touch
Image
Display
Field
Touch
Image
Display
Field
Touch
Touch
Touch
Touch
Summary of Contents for 0862
Page 1: ...No 26 2 Nishishinjuku 1 chome Shinjuku ku Tokyo 163 0512 Japan...
Page 8: ...About this Manual 6 REGIUS Console CS 3 OPERATION MANUAL Ver 1 10 2005 2...
Page 20: ...Ch 1 Safety Precautions Warnings 18 REGIUS Console CS 3 OPERATION MANUAL Ver 1 10 2005 2...
Page 28: ...Ch 2 Operation 26 REGIUS Console CS 3 OPERATION MANUAL Ver 1 10 2005 2...
Page 78: ...Ch 3 Sequence of Examination 76 REGIUS Console CS 3 OPERATION MANUAL Ver 1 10 2005 2...
Page 148: ...Ch 4 Description of Screens 146 REGIUS Console CS 3 OPERATION MANUAL Ver 1 10 2005 2...
Page 172: ...Ch 6 Troubleshooting 170 REGIUS Console CS 3 OPERATION MANUAL Ver 1 10 2005 2...
Page 184: ...Ch 7 Optional Functions 182 REGIUS Console CS 3 OPERATION MANUAL Ver 1 10 2005 2...
Page 194: ...Ch 9 Care Maintenance 192 REGIUS Console CS 3 OPERATION MANUAL Ver 1 10 2005 2...
Page 195: ...REGIUS Console CS 3 OPERATION MANUAL Ver 1 10 2005 2 193 Specifications...
Page 200: ...6...