Ethernet cable
Most high speed connections are made using Ethernet cables. The M3 Sonar FLS must use
T568B termination for RJ45 connections on both ends of the cable.
A
Local Ethernet connection
B
Connection on external network
device
Ethernet cables are available
commercially in different lengths,
colours and categories. Normally,
CAT-5E and CAT-6 cables are used
in local area networks with bandwidths
exceeding 100 Mbit.
Note
It is very important that high-quality Ethernet cables are used. You must use CAT-5E quality
or better. If you use cables with lower bandwidth capacity you will reduce the M3 Sonar
FLS performance.
For 100Base-TX connections only Orange, Orange-White, Green, and Green-White are
required. No cross-over is required for 100Base-TX direct pier to pier connections with
the M3 Sonar FLS.
Minimum cable requirements
Not applicable. This is a commercial cable.